DELAB
-
Brand:DELAB
Description
DELAB
Power Factor Controller NV5/ NV7
- Micro-processor based
- Cos φ and power factor info
- LED indication for individual step
- Auto C/K detection
- Auto and manual operation
- Auto detection of C.T. polarity
- Secondary current info
- Voltage & Frequency info
- THD-I and THD-V info
- Programmable over voltage alarm
- Alarm or fan output
- Programmable software lock
- Flush mount
Power Factor Controller NV6s/ NV8s/ NV14s
- Micro-processor based
- Cos φ and power factor info
- LED indication for individual step
- Auto C/K detection
- Auto and manual operation
- Auto detection of C.T. Polarity
- Secondary current info
- Voltage & Frequency info
- THD-I and THD-V info
- Harmonic spectrum info up to 11th order (for voltage and current)
- Programmable over voltage alarm
- Dedicated alarm output
- Dedicated exhaust fan output
- Automatic alternate switching of utilized capacitor
- Preset/ Auto/ Customized switching program
- Programmable software lock
- Flush Mount
Earth Leakage Relay TM8000s
- True RMS measurement
- Low set/ High set
- Operation hour recording
- Fault & Trip LED indication
- Trip value recording (3 memory)
- Auto Z.C.T. connection check (open/short)\
- Total trip count information
- Self-reclosing/ auto-set
- Programmable relay output
- Programmable software lock
- Flush mount
Earth Fault Relay TM8200s DTL/ TM8300s IDMT
- True RMS measurement
- Low set/ High set
- Operation hour recording
- Fault & Trip LED indication
- Trip value recording (3 memory)
- Selectable 6 IDMT graphs
- Programmable relay output
- Programmable software lock
- Flush mount
Over Current Relay TM 9200s LTI/ TM9300s IDMT
- True RMS measurement
- Low/ high set
- Operation hour recording
- Fault/ Trip LED indication
- 3-tripping history
- Neutral current display
- THD-I display
- Last 30 min. ampere demand
- Maximum ampere demand
- 2 selectable characteristics (DTL/LTI)
- 7 selectable characteristics
- 2 output relays
- Auto shorting of CTs (when unplugged)
- Programmable software lock
- Flush mount
Combined Over Current and Earth Fault Relay TM9000s
- True RMS measurement
- Low set/ High set
- Operation hour recording
- Fault/ Trip LED indication
- 7-tripping history
- Neutral current display
- THD-I display
- Last 30 min. ampere demand
- Maximum ampere demand
- Selectable 6 IDMT graphs
- 2 output relays
- 4 output relays
- 1 programmable digital input
- RS 485 modbus
- Dual setting parameters
- Auto shorting of CT terminals (when unpluggued)
- Programmable software lock
- Flush mount